        Machine fault self check list


        dehumidifier
        LF-826E

                 Fault phenomenon

             Cause of failure

        Solution

                            1、Fault codeE1

                          Humidity sensor failure

                            Humidity sensor wire or sensor falls off

                             Change humidity sensor

                            2、There is no display state on the display screen when the power is turned on

                          Is the power line connected

                          Check the power cord connection

                            Whether the connection line between the main board and the display screen falls off

                            Adjust connection line

                            Is the main board fuse blown

                            Replace the fuse

                           Mainboard or display failure

                            Replace the motherboard or display

                            3、The display shows but the fan does not work

                            Key stuck

                            Change the surface paste or adjust the screws of the control board

                            Loose wiring

                            Check whether the wiring is loose

                            Bad motherboard

                            Replace the motherboard

                            Motor stuck

                            Replace the motor

                            Poor capacitance

                            Change capacitor

                            4、The fan is in normal operation and dehumidification is not obvious

                          Are doors and windows open

                            close the doors and windows

                            Is the filter screen blocked

                            Clean the filter screen

                            Is the humidity too low

                            Adjust humidity setting

                            Is the ambient temperature too low

                           Heating with heating equipment

                            Is there any obstruction at the air outlet

                            Remove obstacles

                            The environmental area is too large

                            Change dehumidifier or supplement dehumidifier

                            5、The whole machine runs normally and has little water output

                            Is the filter screen blocked

                            Clean the filter screen

                           Is there any obstruction at the air outlet

                            Remove obstacles

                            Too little refrigerant or capillary oil resistance

                            Contact manufacturers

                            Is the wind speed working normally

                            Exchange wind speed

                           Is the room temperature above 5 ℃ and below 38 ℃

                            The set temperature is lower than the ambient temperature

                            6、The fan operates normally without dehumidification

                           Is the humidity set higher than the ambient temperature

                            Adjust the humidity value

                            Is the refrigerant leaking

                            Check the copper tube for leakage

                            Compressor not started

                            Compressor wiring loose

                            Check the main board circuit for output

                            If the overload protector is poor, replace the protector

                            Contact the manufacturer for compressor failure

                            If the capacitance is poor, replace the capacitor

                            7、It is noisy during operation

                            Is the machine placed smoothly

                            Adjust machine position

                            Is the filter screen blocked

                            Clean the filter screen

                           Whether the anti vibration screw of compressor is loose

                            Adjust the anti vibration nut of compressor

                            The wind leaves swing a lot

                            Adjusting blade screw

                            Is there any obstruction at the air outlet

                            Remove obstacles

                           Piping collision with structural parts

                            Adjust piping

                            8、water leakage

                           Is there any foreign matter blocking the water pipe

                            Remove foreign matter

                           Sand hole in water pipe

                            Replace the water connection pipe



        Civil aircraft lf-838e / 8150e below

        Fault phenomenon

        Cause of failure

        Solution

                            1、Fault code    E1

                          Temperature sensor failure

                           Replace the temperature sensor

                            2、Fault code     E2

                            Humidity sensor failure

                            Humidity sensor wire or sensor falls off

                            Replace humidity sensor

                            3、382E/582E   E4

                            Water tank not in place

                            Adjust the water tank

                            Full of water

                            Pour water

                            Poor microswitch

                            Replace microswitch

                            Wrong switch wire insertion

                            Adjust the switch wire

                            4、There is no display state on the display screen when the power is turned on

                            Is the power line connected

                            Check the power cord connection

                            Whether the connection line between the main board and the display screen falls off

                            Adjust connection line

                            Is the main board fuse blown

                            Replace the fuse

                            Mainboard or display failure

                            Replace the motherboard or display

                            Key stuck

                           Change the surface paste or adjust the screws of the control board

                            5、The display screen shows that the whole machine is not turned on or the code is garbled or broken

                           Key failure or wrong insertion of flat cable

                            Replace the surface paste or adjust the cable

                           Loose wiring

                            Adjust the wiring

                            Bad motherboard

                            Replace the motherboard

                            Poor display

                            Replace the display

                            6、The dehumidification is not obvious or the water output is small

                           Are doors and windows open

                            close the doors and windows

                           Is the filter screen blocked

                            Clean the filter screen

                           Is the humidity too low

                            Adjust the humidity value

                            Is there any obstruction at the air outlet

                            Remove obstacles

                            The environmental area is too large

                            Change the humidity machine or add the dehumidifier

                            Clogged capillary or filter

                            Contact manufacturers

                            7、The fan operates normally without dehumidification

                            Is the humidity set higher than the ambient humidity

                            Adjust humidity setting

                            Is the ambient temperature too low

                            Heating with heating equipment

                            Is the refrigerant leaking

                            Check the copper tube for leakage

                            Compressor not started

                            Compressor wiring loose

                            Check the main board circuit for output

                            If the overload protector is poor, replace the protector

                            Contact the manufacturer for compressor failure

                            If the capacitance is poor, replace the capacitor

                            8、water leakage

                            Machine imbalance

                            Adjust machine position

                            Outlet pipe blocked

                            Remove foreign matter

                            Water tank not in place

                            Adjust the position of water tank

                            There are sand holes in the water tray

                            Pour in the glass glue

                            Loose connection pipe

                            Tighten the water connection pipe

                            9、It is noisy during operation

                            Is the machine placed smoothly

                            Adjust machine position

                            Is the filter screen blocked

                            Clean the filter screen

                            Whether the anti vibration screw of compressor is loose

                            Adjust the anti vibration nut of compressor

                            The wind leaves swing a lot

                            Adjusting blade screw

                            Air outlet blocked

                            Remove obstructions

                            Piping collision with structural parts

                            Adjust piping


        Failure of wet film humidifier

        Fault phenomenon

        Cause of failure

        Solution

                            1、Fault codeE3

                            Sensor wire not connected

                            Connect the sensor wire

                            Sensor failure

                            Replace the sensor

                            2、No display on the display screen

                            Is the power line connected

                            Check the power supply

                            Whether the connecting wire falls off

                           Connect the connecting wire

                            Is the main board fuse blown

                            Replace the fuse

                            Display failure

                            Replace the display

                            3、Control panel failure

                            Key failure

                            Replace the mask



      • 
        